Homepage kraftelektronik.com
High VoltageHigh CurrentUninteruptible Power SystemsTractionKraftelektronik English  |  Swedish  |  Chinese  |  Russian
 
-
-
-
-
-
MP 1000A Single

Multi Pulse Plater, 1000A, Single module


Multi Pulse Plater


Technical data
Mains Supply 380 - 480V (+/- 10%), 3 phase 45 - 65 Hz
Voltage forward (UFwd ) 5V DC
Output current - Forward (IFwd ) 1000A
- Reverse (IRev) 4000A for max 1,5 ms @ Forward /Reverse time ratio 20 / 1
Output Power - 5000 W
- (IFwd x UFwd x tFwd + IRev x URev x tRev) / (tFwd + tRev) < 5000 W
Pulse Timing - Forward time in 0.1 ms steps 1-3000 ms
- Reverse time in 0.1 ms steps 0.1-3000 ms
- Off time 0 – 3000 ms
Current rise time 50 μs @ 0.1 μH load
Synchronization Up to 30 units can be synchronized
Fault Detection - Cooling failure/overheating
- Over load
- No load
- DC-link error
- Synchronization failure
Communication 2-wire bus Profibus DP or Modbus RTU. Sequence batch program and complex wave forms possible
Cooling Forced air cooled, only heat sinks are exposed to the cooling air. Electronics are in a sealed compartment
Ambient temperature 0 – 40 °C
Environmental protection IP 54
Dimensions W x H x D = 597 x 712 x 520 mm. D = 615 mm inclusive terminals on the rear side
Weight 95 kg
Finish Cabinet in stainless steel
Output busbars Copper, nickel plated
CE marked Yes
Health and Safety The range of Kraft units are CE marked and conform to the Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC (including amendments by the CE Marking Directive 93/68/EEC) for Industrial equipment. This means that a correctly installed Kraft system will not conduct or radiate RF energy which will interfere with other electrical equipment which has been CE marked.